Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-4 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	52
Date	08/04/14
Start Time	11:43:19
Diameter Midpoint
 11.3	136736
 11.8	138993
 12.2	145326
 12.6	158878
 13.1	173485
 13.6	187780
 14.1	204258
 14.6	223288
 15.1	242996
 15.7	271752
 16.3	296752
 16.8	324721
 17.5	358265
 18.1	388693
 18.8	424414
 19.5	461056
 20.2	502519
 20.9	531066
 21.7	570577
 22.5	608441
 23.3	647923
 24.1	676576
 25.0	712273
 25.9	750095
 26.9	776186
 27.9	792627
 28.9	809125
 30.0	818448
 31.1	829504
 32.2	840882
 33.4	837454
 34.6	834285
 35.9	820017
 37.2	804249
 38.5	777675
 40.0	751921
 41.4	714332
 42.9	666398
 44.5	618694
 46.1	572997
 47.8	519062
 49.6	469360
 51.4	420003
 53.3	373463
 55.2	330026
 57.3	283926
 59.4	244811
 61.5	204988
 63.8	170047
 66.1	138067
 68.5	114838
 71.0	93186
 73.7	77747.4
 76.4	62830.6
 79.1	48956.3
 82.0	37272
 85.1	27874.4
 88.2	21158.8
 91.4	16551.8
 94.7	12469.5
 98.2	9565.07
101.8	7363.91
105.5	5670.95
109.4	4212.6
113.4	3076.8
117.6	2335.68
121.9	1564.72
126.3	1177.45
131.0	916.641
135.8	725.22
140.7	547.323
145.9	448.039
151.2	336.11
156.8	303.763
162.5	211.866
168.5	196.662
174.7	193.792
181.1	147.678
187.7	136.368
194.6	114.13
201.7	122.172
209.1	136.166
216.7	111.95
224.7	125.828
232.9	114.126
241.4	93.9622
250.3	77.8148
259.5	85.7327
269.0	86.3435
278.8	85.3423
289.0	97.0707
299.6	99.1416
310.6	83.6466
322.0	84.0722
333.8	83.5319
346.0	59.0711
358.7	61.1234
371.8	65.1033
385.4	54.0957
399.5	71.6646
414.2	83.9768
429.4	48.7739
445.1	53.5531
461.4	46.8832
478.3	41.1547
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.7209
High Voltage	9974.37
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1081.44
Median(nm)	30.8087
Mean(nm)	33.0326
Geo. Mean(nm)	30.3048
Mode(nm)	32.1968
Geo. Std. Dev.	1.51847
Total Concentration(#/cm)	2.51096e+007
Comment	